Divided Highway Plaque - Safety Systems Hawaii, Inc. Online Warehouse

Alternate Views:

Divided Highway Plaque

Aluminum backed sign with black silk screen arrow on yellow sheeting of either Engineer grade or High Intensity grade reflectivity. Mounting holes are the industry standard of 3/8".

State Hawaii: All signs = High Intensity
C&C Honolulu: All signs = Engineer

Engineer Grade is the most economical, but least reflective and is often placed in neighborhoods and on roads with less travel. Engineer Grade is designed to last for at least 7 years outdoors.

High Intensity Grade is three times more reflective than Engineer Grade and is most often used on city streets as well as roads with frequent night traffic. High Intensity Grade is designed to last for at least 10 years outdoors.

View additional details


All prices are FOB Honolulu, Hawaii.
Items Regular price Quantity
Item #: SW6-1p-E A24X18
DIVIDED HIGHWAY plaque, engineer grade 24"X18"
$ 29.51 USD
Item #: SW6-1p-H A24X18
DIVIDED HIGHWAY plaque, hi-intensiity grade 24"X18"
$ 39.69 USD


Additional Details

MUTCD Section 2A.14 Word Messages
Standard: All word messages shall use standard wording and letters. Word message warning signs are also diamond shaped yellow signs with a black border. Lettering shall be in capital letters as provided in the “Standard Highway Signs” book, except as indicated in the Option below.

Guidance: Word messages should be as brief as possible and the lettering should be large enough to provide the necessary legibility distance. A minimum specific ratio, such as 25 mm (1 in) of letter height per 12 m (40 ft) of legibility distance, should be used. Abbreviations should be kept to a minimum, and should include only those that are commonly recognized and understood, such as AVE (for Avenue), BLVD (for Boulevard), N (for North), or JCT (for Junction).

Support: Some research indicates that a ratio of 25 mm (1 in) of letter height per 10 m (33 ft) of legibility distance could be beneficial.

Option: Word messages on street name signs and destinations on guide signs may be composed of a combination of lower-case letters with initial upper-case letters.

MUTCD -Section 2C.01 Function of Warning Signs

Standard: The use of warning signs shall be based on an engineering study or on engineering judgment.

Guidance: Warning signs should be placed so that they provide adequate PIEV time. Warning signs should not be placed too far in advance of the condition, such that drivers might tend to forget the warning because of other driving distractions, especially in urban areas. Minimum spacing between warning signs with different messages should be based on the estimated PIEV time for driver comprehension of and reaction to the second sign.The effectiveness of the placement of warning signs should be periodically evaluated under both day and night conditions.
The use of warning signs should be kept to a minimum as the unnecessary use of warning signs tends to breed disrespect for all signs. In situations where the condition or activity is seasonal or temporary, the warning sign should be removed or covered when the condition or activity does not exist.

Support: Warning signs call attention to unexpected conditions on or adjacent to a highway or street and to situations that might not be readily apparent to road users. Warning signs alert road users to conditions that might call for a reduction of speed or an action in the interest of safety and efficient traffic operations.

MUTCD Section 2C.44 Design of Supplemental Plaques A supplemental plaque shall have the same color legend, border, and background as the warning sign with which it is displayed. Supplemental plaques shall be square or rectangular.

MUTCD Section 2C.43 Use of Supplemental Plaques
Option: A supplemental plaque may be displayed with a warning sign when engineering judgment indicates that road users require additional information beyond that contained in the main message of the warning sign.
Standard: Supplemental plaques shall be used only in combination with warning or regulatory signs. They shall not be mounted alone or displayed alone. If used, a supplemental plaque shall be installed on the same post(s) as the warning sign.

September Training

First Aid/CPR Training
09SEP08

3M Respiratory Train-the-Trainer
16SEP08

Call our Customer Care Staff at 808/847.4017 to reserve a spot in any of our training seminars. Call quick as classes fill up fast!

Find out about training at your facility or jobsite - just ask for Clifford.


September Events

Labor Day
01SEP08
Federal, State, C&C & GCLA Holiday

Patriot Day
11SEP08
We will never forget.

Primary Election Day
20SEP08
Don't forget to vote!



October Training

Construction Health & Safety
with Bernard Tom
04OCT08 - 10hrs
06-07OCT08 for additional 20 hours
Register quick as these classes are limited to 32 people per class!

First Aid/CPR Training
14OCT08

Fall Protection
21OCT08

Call our Customer Care Staff at 808/847.4017 to reserve a spot in any of our training seminars. Call quick as classes fill up fast!

Find out about training at your facility or jobsite - just ask for Clifford.